Many processes and stored goods depend on stable conditions. Food production and storage need documented temperatures for HACCP, pharmaceuticals and blood products need controlled storage, laboratories and server rooms need a stable climate, and museums and archives need controlled humidity. The common requirement is continuous measurement, reliable logging and an alarm when a limit is exceeded.
The CL series data loggers measure temperature, humidity and dew point, combined with CO2, CO, particulate matter (PM1, PM2.5, PM10), TVOC or gases such as O2, NH3 and H2S depending on the model. They log data internally, communicate over RS-485 and Ethernet with PoE using Modbus RTU, Modbus TCP and MQTT, and are also available with Wi-Fi. Liquid leakage detection uses sensing cable laid along pipes and floors, and signals a leak to the monitoring system.
Where sensors are already installed, temperature input modules read thermocouples, RTDs and thermistors directly. RS-485 modules such as the M-7000 series do this over Modbus RTU, Ethernet modules over Modbus TCP, and wireless I/O covers locations that are difficult to cable.
Alert modules play voice or tone messages and drive sirens, and iKAN LED message displays show measured values or alarm texts where staff can see them. Combined with an edge controller or an I/O module with logic rules, alarms can also be sent by e-mail.
For HACCP and quality systems, measurements must be stored with time stamps and kept available for inspection. Data can be logged locally in the sensor or module, collected by an edge controller, or stored centrally in SCADA, a database or IoTstar.
Each cold room and freezer gets a temperature sensor read by M-7000 RTD input modules on a shared RS-485 line, and a CL series logger monitors humidity and CO2 in the packing area. An edge controller collects all values, stores them with time stamps for the HACCP records and sends an e-mail and switches a siren if a room stays above its limit for longer than the set delay.
Send us a list of rooms or measuring points, and we will propose sensors, logging and alarm handling.
The ACS-10V-MF CR is an RFID proximity card reader for access control, combining door access, voice guidance and elevator floor control in one unit. It reads Mifare Classic, Ultralight and DESFire cards and can store up to 8192 cards, making it suited to community door access and elevator control.The reader includes electric door lock control and door position detection, plus an anti-sabotage micro switch. It keeps access records and provides a built-in RTC and WDT. Elevator floor control supports up to 16 floors.Connectivity covers a 10/100Base-T(X) Ethernet port, an RS-485 port and CAN (ISO-11898-2). Four digital inputs and two Form C relay outputs support door and system integration. The unit is wall mounted and rated for -20 ~ +60 °C operation.ApplicationsCommunity door access controlElevator access and floor controlAccess control systems requiring door position monitoring
The ACS-10V-MF-TC is an RFID proximity card reader for access control systems. It reads ISO 14443 A cards, including Mifare Classic, Ultralight and DESFire, and combines door access control, voice guidance and elevator floor control in one unit.This -TC ordering code is the Chinese voice version of the reader. The built-in voice message function gives users audible feedback at the door. The unit has an Ethernet port, an RS-485 port and a CAN bus interface, so it can be integrated into different access control architectures.Door security is handled by an electric door lock output, door position detection and an anti-sabotage micro switch. Access records are kept on the device, and it can store up to 8192 cards. It is suited to community door access and elevator control installations.ApplicationsCommunity door access controlElevator floor controlAccess control systems
The ACS-10VP-MF is a wall-mounted RFID proximity card reader for access control. It reads Mifare Classic, Ultralight and DESFire cards and combines door access, voice guidance and elevator floor control in one unit. This ordering code is the English voice version.Its Ethernet port supports Power over Ethernet (IEEE 802.3af, Class 1), so the reader can be powered from the same cable as its network connection. An RS-485 port is also provided for serial communication. Two digital inputs and two Form C relay outputs allow the reader to handle door lock control and door position detection, and a micro switch provides anti-sabotage detection.Stores up to 8192 cards and provides access records.Supports elevator floor control for up to 32 floors.Built-in RTC and WDT for timekeeping and watchdog protection.ApplicationsCommunity door accessElevator controlAccess control systems
The ACS-11-MF is a proximity card reader with a built-in keypad, designed for access control installations where credentials are presented by card, by code or by both. It reads ISO 14443 A cards including Mifare Classic, Ultralight and DESFire, and gives spoken feedback through its built-in voice message function.Beyond credential reading, the unit controls an electric door lock, monitors door position and supports elevator floor control of up to 32 floors. It stores up to 8192 cards and keeps access records. An anti-sabotage micro switch and a choice of Ethernet, RS-485 or CAN communication suit it to engineers building networked access control systems.The reader is wall mounted and rated for an operating temperature of -20 ~ +60 °C. Its 2.0 W consumption and reverse polarity protection simplify integration into existing low-voltage access control wiring.ApplicationsCommunity door accessElevator floor controlAccess control systems
Logging intervals, alarm delays, sensor placement and data retention for cold rooms and freezers, and which ICP DAS hardware fits each task.
Sensing cable or spot probe, how to divide a room into zones, and how to route leak and cable-break alarms to staff, BMS and SCADA.
What CO2, particle, TVOC and CO readings tell you, how to choose a CL series data logger, and how to connect it to a BMS or SCADA system.
Vi kjenner ICP DAS-sortimentet og hjelper deg med å finne riktig modul, tilbehør eller reservedel.
Kontakt teknisk salg