Temperature sensors for building automation: RTD, NTC or 0–10 V
Pt100, Pt1000, NTC thermistor or 0–10 V transmitter: wiring, cable length, accuracy and which ICP DAS input modules read each sensor type.
I/O, BACnet and Modbus gateways and dedicated modules for HVAC, lighting, access control and technical monitoring.
Building automation connects HVAC, lighting, access control, alarms and metering to a building management system (BMS) or SCADA. ICP DAS products are typically used where signals have to be collected from many points in a building, or where devices with different protocols need to exchange data.
RS-485 modules such as the M-7000 series collect signals over long cable runs on a single twisted pair using Modbus RTU. Where the building has a structured Ethernet network, Ethernet I/O such as the ET-7000 and ET-2200 series connects directly over Modbus TCP and is configured from a web browser. PoE models take power and data over one cable, which simplifies installation in ceilings and small cabinets without a local 24 V supply. Wireless I/O with ZigBee or Wi-Fi covers points where new cabling is impractical.
Building systems mix protocols. ICP DAS gateways make Modbus RTU and Modbus TCP devices available as BACnet/IP objects, connect Modbus TCP systems to BACnet MS/TP networks, and include a gateway for DALI lighting. BACnet/IP I/O modules connect signals directly to a BACnet BMS without a gateway. Serial device servers make older RS-232 and RS-485 equipment reachable over the network without replacing it.
The building and home automation range adds modules for specific jobs: lighting control modules with relay outputs and load current measurement, card readers for access control, alert modules with recorded voice messages, sirens and fan coil control. They use standard interfaces such as RS-485 and Ethernet, so the BMS integrates them like any other Modbus device.
TouchPAD panels provide local control and status screens for rooms and plant, and iKAN LED message displays show alarms or status text in technical areas.
In a building with a BACnet/IP BMS, each technical room gets M-7000 modules that read Pt100 sensors, door contacts and leak alarms over RS-485. One BACnet/IP to Modbus RTU gateway per RS-485 segment publishes the values as BACnet objects, so the BMS reads them like any other BACnet device and no custom driver is required.
Send us the I/O list or a description of the installation, and we will suggest suitable modules and gateways.
The PET-7017-10 is a PoE-powered Ethernet analog input module for engineers who need voltage or current measurement on a networked I/O node. Its inputs can be set as 10 differential or 20 single-ended channels in software, and each channel can be given its own range, so one module can serve mixed sensor types on the same network.Each channel offers a choice of voltage ranges from ±150 mV to ±10 V and current ranges of ±20 mA, 0 ~ 20 mA and 4 ~ 20 mA, selected with jumpers. Resolution is 16-bit, and the module has two sampling modes: normal mode at 10 Hz total and fast mode at 50 Hz total. Open wire detection is available for 4 ~ 20 mA inputs, and differential channels are rated for 240 Vrms overvoltage protection.Configuration and monitoring are handled through a built-in web server with Web HMI, and the module supports Modbus TCP and Modbus UDP. Access is controlled by ID, password and IP filter. The unit is powered either from PoE (IEEE 802.3af, Class 1) or from a +12 ~ +48 VDC terminal block, and it mounts on a DIN rail.ApplicationsBuilding automationFactory automationMachine automationRemote maintenanceRemote diagnosisTesting equipment
AR-200 CR is a dynamic signal acquisition module for vibration monitoring and analysis. It accepts two IEPE accelerometers, each supplied with a built-in 3 mA excitation current, and digitises the signals with a 16-bit converter. Sampling of both channels runs simultaneously, at rates up to 200 kHz per channel.Recordings are written to a Micro SD card, so data can be taken away and analysed offline. Capture can be started by a push button, a schedule, an analog threshold, a digital input or a remote command from the supplied utility on a host PC, which also lets you set the sampling rate and scheduling for each application. A single relay output and one digital input add basic event handling to the unit.The logger suits panel or machine installations that need to run unattended. It works from a wide +10 to +30 VDC supply, operates from -25 to +75 °C, and provides 4 kV contact ESD protection on all terminals. Mounting is by wall or DIN-rail.ApplicationsVibration monitoring and analysisIndustrial automationFactory automationProcess automation
The AR-400 is a dynamic signal acquisition module for vibration monitoring and analysis. It samples four channels simultaneously with 16-bit resolution and supplies a built-in 3 mA excitation current for IEPE accelerometers, so compatible sensors can be connected directly without an external supply.Acquired data is written to a micro SDHC card (4 to 32 GB), allowing offline analysis after capture. Recording can be started by push button, schedule, analog threshold, digital input or remote trigger from the utility software installed on a host PC, which also handles sample rate and sampling schedule settings.Suited to condition monitoring setups where vibration data must be captured at defined times or on defined events.Includes a relay output (Form A, 5A@250 VAC) and a digital input for use within trigger or control logic.ApplicationsVibration monitoring and analysisIndustrial automationFactory automationProcess automation
CL-202-E CR is a data logger module for monitoring indoor air quality and climate conditions. It measures CO2 with a non-dispersive infrared (NDIR) sensor, alongside temperature, relative humidity and dew point, and records the results with date and time stamps for later analysis.The module offers an RS-485 port and an Ethernet port with PoE support, so it can be integrated into existing HMI or SCADA systems over DCON, Modbus RTU, Modbus TCP or MQTT. Real-time readings can be viewed from the iAir Utility, the iOS or Android apps, or a web browser, provided the logger is on the same local network. Logged data can be exported to CSV for analysis in standard spreadsheet or industry software.Relay output for alarm signalling or control of IAQ equipmentCeiling or wall mounting, IP20 housing, Ø 150 x 53 mmOperating temperature 0 ~ 50°C, non-condensing humidity range 10 ~ 90% RHApplicationsTransportation of food or pharmaceuticalsFood and beverage industry (HACCP)Blood stations and pharmaciesBuilding and energy managementWarehouse managementMuseums, archives and galleriesIndoor or underground parking lot air quality monitoring
Pt100, Pt1000, NTC thermistor or 0–10 V transmitter: wiring, cable length, accuracy and which ICP DAS input modules read each sensor type.
PoE classes, power budgets, switches and injectors, and the ICP DAS PoE I/O series for ceilings, risers and small technical rooms.
How a Modbus to BACnet gateway maps registers to BACnet objects, when MS/TP is involved, and which ICP DAS gateway fits each direction.