SG-3000
The SG-3011-G CR converts a thermocouple signal into a standard analogue output for control and monitoring systems. A microprocessor-controlled 24-bit A/D converter samples both the thermocouple and the cold junction input, and linearisation and cold junction compensation are applied to the reading.The module accepts a broad selection of thermocouple types, including J, K, T, E, R, S, B, N, C, L, M and L2 (DIN43710). Its CJC offset can be adjusted, open thermocouple detection is provided, and the response time can be switched between 0.5 ms and 100 ms.Three-way isolation rated at 1000 VDC, with an internally isolated supply for the input and output circuitryReverse polarity protection on the power input (+10 ~ +30 VDC)Its DIN-rail housing and an operating range of -25 ~ +75 °C make it suitable for building, factory and machine automation, as well as remote maintenance, remote diagnosis and test equipment.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The SG-3011H-G converts a thermocouple input into a standardised analogue output for use in control and monitoring systems. A microprocessor-controlled 24-bit A/D converter samples the thermocouple and the cold junction compensation input, and linearisation and cold junction compensation are applied to the reading. It supports twelve thermocouple types, from J and K through to R, S, B and the DIN43710 L2 type.Response time is switch selectable between 0.5 ms and 100 ms, so the module can be set for fast-changing signals or for slower, steadier readings. Adjustable CJC offset and open thermocouple detection help with commissioning and fault diagnosis. The internally isolated power supply for the input and output circuitry provides three-way isolation rated at 1000 VDC.The module mounts on a standard DIN rail and is specified for an operating range of -25 ~ +75 °C, making it suitable for cabinets in demanding environments. Its 0 ~ 10 VDC and 0 ~ 20 mA outputs are supplied with a 12-bit resolution and ±0.1% of FSR accuracy.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The SG-3013-G CR conditions a single RTD sensor signal and delivers it as a standard voltage or current output for control and monitoring equipment. It accepts Pt100, Ni 120 and Pt1000 sensors, and internal configuration switches let you adjust the input and output ranges without changing the hardware.Isolation and accuracy: Input, output and power are separated by 1000 VDC three-way isolation, and the module holds an accuracy of ±0.1% of full range with a 100 ms response time. It is rated for operation from -25 °C to 75 °C, so it suits installations with a wide temperature range.Installation: The module mounts on a standard DIN rail in a 25 mm x 114 mm x 70 mm housing. Reverse polarity protection is fitted on the supply input, and the ordering code is listed as RoHS compliant.
The SG-3016-80-G CR is a signal conditioning module that takes a millivolt-level voltage input and delivers a voltage or current output for the rest of the control system. It suits engineers who need to condition strain gauge type signals on a DIN-rail without building a custom interface.Input and output ranges are selected through internal configuration switches, so the same module can be matched to different sensor spans and controller inputs. Three VRs (Zero, Span and Exci) allow the accuracy of the input and output range to be calibrated, and an LED shows whether the module is functioning correctly. The typical bandwidth is 80 Hz.Three-way isolation of 1000 VDC separates input, output and power, and the module operates from a +10 ~ +30 VDC supply with reverse polarity protection. The -G variant is listed with the RoHS-compliant strain gauge signal conditioner description.ApplicationsStrain gauge signal conditioningConverting low-level millivolt sensor signals to standard voltage or current outputsIsolated signal conditioning in industrial control panels
SG-3016-G CR is a DIN-rail signal conditioning module that takes a millivolt-level voltage input and delivers a standard voltage or current output for PLCs, data acquisition systems and other control equipment. Input ranges from ±10 mV to ±100 mV can be matched to outputs of ±5 V, ±10 V, 0~5 V, 0~10 V or 0~20 mA through internal configuration switches.Input, output and power circuits are separated by 1000 VDC three-way isolation, which helps prevent ground loops and protects downstream equipment from interference. An integrated excitation voltage output of 1 to +10 VDC, rated for up to 20 mA, supports bridge-type sensors. Three potentiometers (Zero, Span and Exci) allow the input and output range to be calibrated for accuracy of ±0.1% of full range.Accuracy of ±0.1% of full range, typically 600 Hz bandwidthLED indicator for power and communication statusReverse polarity protection on the +10 to +30 VDC supplyOperating temperature -25 °C to 75 °C, humidity 5 to 95% non-condensingApplicationsStrain gauge signal conditioningConverting low-level millivolt sensor signals to standard voltage or current signals for control and monitoring systemsIsolated signal transmission between sensors and industrial controllers
The SG-3071-G CR converts a DC voltage input into either a voltage or a current output. It accepts bipolar (±5 V, ±10 V) or unipolar (0 ~ 5 V, 0 ~ 10 V) input ranges, and the input and output ranges are selected through internal configuration switches, so no reprogramming is needed.Input, output and power circuits are separated by 1000 VDC three-way isolation. Two VRs (Zero and Span) allow the accuracy of the input and output range to be calibrated, and an LED shows whether the module is operating correctly. The module mounts on a standard DIN rail and is rated for an operating range of -25 °C ~ 75 °C.Voltage output pairs with bipolar input; current output pairs with unipolar input.Typical bandwidth is 1 KHz.ApplicationsConverting DC voltage signals to standard voltage or current signalsSignal isolation between input, output and power circuitsInterfacing voltage sources with current-loop inputs in wide-temperature industrial environments
The SG-3081-G takes a unipolar 0 to 20 mA or 4 to 20 mA DC current input and delivers a 0 to 5 VDC, 0 to 10 VDC, 0 to 20 mA or 4 to 20 mA output. Input, output and power circuits are separated by 1000 VDC, which helps keep signal paths clean in noisy industrial installations.Input and output ranges are chosen through internal configuration switches, so the same module can be matched to different controllers without changing the hardware. Two potentiometers, labelled Zero and Span, allow the accuracy of the chosen range to be fine-tuned, and an LED indicates that the module is operating correctly.Suits engineers needing isolated current-to-voltage or current-to-current conversion on a DIN rail.ApplicationsConverting 0/4 to 20 mA sensor or transmitter signals to 0 to 5 V or 0 to 10 V inputsIsolated current-to-current signal conversion between control systems
SG-3383 CR is a DC current signal splitter that accepts one 4 to 20 mA input and provides three optically isolated 4 to 20 mA outputs, each linearly related to the input. It offers a cost-effective way to send one process signal to three separate devices.The input is filtered, amplified and split before passing through an opto-coupler to the output stages. Three-way isolation between input, output and power, together with 4 kV EFT protection on the power line and 8 kV ESD protection, helps with ground loop elimination, common mode rejection and noise reduction. Each output has its own zero and span adjustment for calibrating output range accuracy, and an LED indicates module status.Typical uses include splitting a signal for control and validation, separating output devices, or providing redundancy so that one device failure does not disable the entire loop. The module is designed for DIN-rail or wall mounting.ApplicationsBuilding AutomationFactory AutomationMachine AutomationRemote MaintenanceRemote DiagnosisTesting Equipment
The SG-3784M converts four 4~20 mA DC current signals into four PWM outputs. Each duty cycle runs linearly from 1 to 100% across the 4~20 mA input range, which makes it a straightforward option where a current loop signal must drive a PWM-controlled load.The PWM frequency is set between 600 and 800 Hz and is adjusted with the four front-panel buttons. A 2.7-inch monochrome graphic LCD shows the duty ratio and frequency of all four PWM channels at once, so commissioning and checking can be done on site without a PC. Input accuracy is ±0.1% of full range.Electrical noise immunity is rated at ±4 kV for ESD (contact, each terminal) and ±4 kV for EFT on the power line. The module runs from a 10 ~ 30 VDC supply with reverse polarity protection and mounts on DIN-rail or wall, with an operating range of -25 ~ +75 °C.ApplicationsHeating systems in buildingsVentilation systemsControlling servo-assisted diaphragm valves
The tSG-3781B takes one 4 ~ 20 mA DC current signal and maps it linearly onto a PWM output, so a current loop can drive equipment that expects a pulse-width signal. The PWM duty cycle spans 1 to 100%, and the output runs in continuous mode from a source-type stage.Output frequency is adjustable between 600 Hz and 800 Hz using the setting buttons on the bottom side of the module. A monochrome graphics LCD with a 26 x 26 mm viewing area shows the current duty cycle and frequency.The module is rated for a +10 ~ +30 VDC supply with reverse polarity protection, operates from -25 ~ +75 °C, and mounts on DIN-rail or wall. It is a suitable choice for building heating and ventilation control and for servo-assisted diaphragm valve actuation.ApplicationsHeating system in buildingsVentilation systemControlling servo-assisted diaphragm valve
The tSG-3781L CR is a single-channel DC current input signal conditioner that converts a 4 ~ 20 mA input into a PWM output. The PWM duty cycle covers 0% to 100% and follows the 4 ~ 20 mA input in a linear relationship, making it a practical interface between a current loop signal and a PWM-controlled device.Output frequency is set between 600 Hz and 800 Hz using the push buttons located on the left side of the module. A monochrome LCD displays the duty cycle and frequency of the PWM output, so settings can be checked on site without additional tools.Typical applications include building heating and ventilation systems, and servo-assisted diaphragm valve control.DIN-rail or wall mounting with a 10 ~ +30 VDC supply input.ApplicationsHeating systems in buildingsVentilation systemsControlling servo-assisted diaphragm valves