Hopp til hovedinnhold Hopp til søk Gå til hovednavigasjon

GPS-721-MRTU GPS Receiver Module with RS-232/RS-485, NMEA, DCON, Modbus RTU

Produktinformasjon "GPS-721-MRTU GPS Receiver Module with RS-232/RS-485, NMEA, DCON, Modbus RTU"

The GPS-721-MRTU is a remote GPS receiver module that delivers position data over RS-232 or RS-485 using NMEA 0183, DCON or Modbus RTU. Its 66-channel tracking and MediaTek chipset suit engineers who need reliable positioning data inside a compact DIN-rail enclosure.

Timing and I/O: A 100 ms PPS pulse per second output supports precise timekeeping and time measurement, and the PPS function can be combined with another source for time synchronisation. A single open-collector digital output is also provided for general-purpose switching.

The module accepts a 10 to 30 VDC non-regulated supply with reverse polarity protection and operates from -25 to +75 °C. A 5 m GPS antenna (ANT-115-03) is included with this ordering code.

Applications

  • Automotive navigation
  • Personal positioning and navigation
  • Marine navigation
  • Satellite time correction
  • Precise timekeeping and time measurement
Product type: GPS receiver module
Interface: RS-232, RS-485
Protocol: DCON, Modbus RTU, NMEA 0183
Digital outputs: 1
Ports: 2
Power input: 10 ~ 30 VDC
Operating temperature: -25 ~ +75 °C
Mounting: DIN-rail
Housing: Plastic

Spesifikasjoner

LED Indicators
Status1 x Power/Communication
3 x GPS
GPS/GNSS
Acquisition TimeCold Start (Open Sky) = 33 s (typical)
ChipMediaTek solution
FrequencyL1 1575.42 MHz, C/A code
Max. Altitude<18,000 m
Max. Velocity<515 m/s
Position AccuracyAutonomous: 2D RMS
SBAS: 2.5m (depends on accuracy of correction data)
ProtocolNMEA 0183 (9600 bps, N81 Fixed)
SensitivityTracking: Up to -165 dBm
Cold start: Up to -148 dBm
Support Channels66
1 PPSPulse per second output (Default 100 ms pulse/sec)
Digital Output
Channels1 (Sink)
TypeNon-isolated Open Collector
Load Voltage+5 VDC~ +30 VDC
Load Current100 mA
COM Ports
Ports1x RS-232, 1x RS-485
Baud Rate1200 ~ 115200 bps
Data FormatN81, N82, E81, O81
ProtocolRS-232: DCON, Modbus RTU or NMEA 0183 (9600bps,N81 fixed)
RS-485: DCON or Modbus RTU
Power
Input Range+10 VDC ~ +30 VDC (Non-regulated)
Consumption2.5 W
Mechanical
CasingPlastic
Dimensions (mm)72 x 117 x 35 (W x L x D)
Weight200 g
Environment
Operating Temperature-25 ~ +75°C
Storage Temperature-40 ~ +80°C
Humidity5 ~ 95% RH, Non-condensing

Spesifikasjoner som oppgitt av produsenten. Med forbehold om endringer.

0 av 0 vurderinger

Gjennomsnittlig vurdering av 0 av 5 stjerner

Legg igjen en anmeldelse!