PIR-230-WF PIR Motion and Temperature/Humidity Sensor, Wi-Fi/PoE/RS-485
Ceiling or surface-mount PIR motion, temperature and humidity sensor module with a relay output, RS-485, Ethernet PoE and Wi-Fi, supporting DCON, Modbus RTU/TCP and MQTT.
- 360° PIR detection up to 4 m height and 8 m maximum diameter
- Temperature sensing from -40 ~ +120°C and humidity sensing from 0 ~ 100% RH
- Form C relay output rated NO 10 A and NC 6 A at 250 VAC
- Two wet-contact digital inputs with 70 ~ 220 VAC ON level
- RS-485 and Ethernet/PoE ports plus Wi-Fi (IEEE 802.11 b/g/n) in infrastructure or limited AP mode
- DCON, Modbus RTU, Modbus TCP and MQTT protocol support
2 285,47 kr per stk.
| 1–9 stk. | 2 285,47 kr | |
|---|---|---|
| 10–30 stk. | 2 212,75 kr | −3 % |
| 31+ stk. | 2 171,20 kr | −5 % |
Produktinformasjon "PIR-230-WF PIR Motion and Temperature/Humidity Sensor, Wi-Fi/PoE/RS-485"
The PIR-230-WF combines a 360° passive infrared motion detector with a temperature and humidity sensor in one ceiling or surface-mount module. Its relay output can switch a connected light when motion is detected, which suits automated lighting in shared spaces.
Communication is available over RS-485, Ethernet with PoE and Wi-Fi, with DCON, Modbus RTU, Modbus TCP and MQTT supported for integration with HMI, SCADA or central control systems. The module can also serve as a fire alarm using a programmable 65°C threshold.
Installation is simplified by a screw-free quick-connect connector and DIP and rotary switches. The housing is UL94-V2 rated, and the white finish suits interior décor. The manufacturer lists this variant for Asia only.
Applications
- Lighting and exhaust fans in public toilets
- Common lighting in staircases
- Lighting in parking areas
- Garden lights
- Lighting for changing rooms in shops
- Corridor lighting
| Product type: | PIR motion sensor |
|---|---|
| Interface: | Ethernet, RS-485, Wi-Fi |
| Protocol: | DCON, Modbus RTU, Modbus TCP, MQTT |
| Digital inputs: | 2 |
| Relay outputs: | 1 |
| Ports: | 2 |
| PoE: | Yes |
| Power input: | 18 ~ 48 VDC, PoE |
| Operating temperature: | 0 ~ +35 °C |
| Mounting: | Ceiling / surface |
| Housing: | UL94-V2 |
Spesifikasjoner
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal, ±8 kV Air for Random Point |
| LED Indicators | |
| Status | Yes, 1 as Power/Communication Indicator. 1 as Alarm Indicator |
| PIR | |
| Detection Height | 4 m Max. |
| Detection Field of View | 360°; 8 m Diameter Max. |
| Lux Control Level | Hardware: 2 modes (Dawn and dust) / Software: 5-step |
| Delay Time | Hardware: 8-step Switch-selectable (seconds): 6, 16, 33, 66, 131, 262, 524, 1049 Software: 16-step (seconds): 2, 4, 6, 8, 16, 33, 49, 66, 131, 262, 393, 524, 1049, 2097, 3146, 4194 |
| PIR Response Time | 1 second |
| Temperature Measurement | |
| Fire Alarm | 65°C (Programmable) |
| Range | -40 ~ +120°C |
| Resolution | 0.01°C |
| Accuracy | ±0.5°C (at 0 ~ 60°C) |
| Humidity Measurement | |
| Range | 0 ~ 100% RH |
| Resolution | 0.01% RH |
| Accuracy | ±5% RH |
| Wi-Fi | |
| Transmission Distance (LoS) | 50 m (LOS) |
| Standard Supported | Wi-Fi: IEEE 802.11 b/g/n |
| Mode | Infrastructure/ Limited AP |
| Encryption | WEP, WPA ,WPA2 |
| Digital Input | |
| Channels | 2 |
| Type | Wet Contact |
| ON Voltage Level | 70 ~ 220 VAC |
| OFF Voltage Level | 20 VAC Max. |
| Input Impedance | 68 KΩ, 1 W |
| Relay Output | |
| Channels | 1 |
| Type | Power Relay, Form C |
| Contact Rating | NO: 10 A @ 250 VAC NC: 6 A @ 250 VAC |
| COM Ports | |
| Ports | 1 x RS-485 1 x Ethernet/PoE |
| Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
| Protocol | DCON, Modbus RTU, Modbus TCP, MQTT |
| Power | |
| Reverse Polarity Protection | Yes |
| Input Range | 18 ~ 48 VDC, PoE |
| Consumption | 3 W |
| Mechanical | |
| Dimensions (mm) | Ø150 x 53 (Ø x H) |
| Installation | Ceiling /surface mounted |
| Ingress Protection Rating | IP20 |
| Environment | |
| Operating Temperature | 0 ~ +35°C |
| Storage Temperature | -30 ~ +80°C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Spesifikasjoner som oppgitt av produsenten. Med forbehold om endringer.