Hopp til hovedinnhold Hopp til søk Gå til hovednavigasjon

CL-203-WF IAQ Data Logger, CO/CO2/Temperature/Humidity, Wi-Fi and PoE

Produktinformasjon "CL-203-WF IAQ Data Logger, CO/CO2/Temperature/Humidity, Wi-Fi and PoE"

CL-203-WF CR is an indoor air quality monitoring module that logs carbon monoxide, carbon dioxide, temperature, humidity and dew point. Each reading is stored with date and time stamps, and up to 450,000 records can be downloaded later.

Connectivity covers RS-485, Ethernet and Wi-Fi, so the module can feed existing HMI or SCADA systems over DCON, Modbus RTU or Modbus TCP. Where Ethernet is used, MQTT is also available. The relay output can drive an alarm or control IAQ equipment directly.

Real-time readings can be viewed from the supplied utility or the iOS and Android apps when the device is on the same local network. Power can come from PoE or a DC terminal block, and the unit mounts on a ceiling or wall.

Applications

  • Transportation of food or pharmaceuticals
  • Food and beverage industry (HACCP)
  • Blood stations and pharmacies
  • Building and energy management
  • Warehouse management
  • Museums, archives and galleries
  • Indoor or underground parking lot air quality monitoring
Product type: Data logger module
Interface: Ethernet, RS-485, Wi-Fi
Protocol: DCON, Modbus RTU, Modbus TCP, MQTT
Relay outputs: 1 x Form A
Ports: 2
PoE: IEEE 802.3af, Class 1
Power input: +12 ~ +48 VDC, PoE
Operating temperature: 0 ~ 50°C
Mounting: Ceiling, wall

Spesifikasjoner

CPU Module
Watchdog TimerYes, Module (2.3 seconds), Communication (Programmable)
System
SecurityIP filter (whitelist) and Password (web)
AlarmCO/CO2/RH/Temperature
Real Time ClockYes
Data LoggerYes, up to 450,000 records
Temperature Measurement
Range-10 ~ +50°C
Resolution0.1°C
Accuracy±0.6°C
Humidity Measurement
Range0 ~ 100% RH, Non-condensing
Resolution0.1% RH, Non-condensing
Accuracy±5% RH, Non-condensing
CO Measurement
Range0 to 1000 ppm (Electrochemical)
Resolution1 ppm
Accuracy±5% of measured value
Response Time30 seconds
Warm-up Time5 minutes
CO2 Measurement
Range0 to 9999 ppm (NDIR)
Resolution1 ppm
Accuracy±40 ppm ±3% of measured value
Response Time120 seconds
Warm-up Time5 minutes
Wi-Fi
Transmission Distance (LoS)50 meters (LOS)
Standard SupportedIEEE 802.11 b/g/n
RX Sensitivity-95.7 dBm @ 1 DSSS, -74.0 dBm @ 54 OFDM
Output Power18 dBm @ 1 DSSS, 14.5 dBm @ 54 OFDM
ModeInfrastructure & Limited AP
EncryptionWEP, WPA and WPA2
Antenna1 dBi (PCB Antenna)
Relay Output
Channels1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports1 x RS-485
1 x Ethernet
Baud Rate1200 ~ 115200 bps
ProtocolDCON and Modbus/RTU (RS-485)
Modbus TCP (Ethernet, Wi-Fi)
MQTT (Ethernet)
Power
ConsumptionNon-PoE: 1.7 W (Max.)
PoE: 1.8 W (Max.)
Powered from Terminal Block+12 ~ +48 VDC
Mechanical
Dimensions (mm)Ø 150 x 53 (Ø x H)
InstallationCeiling Mounting/Wall Mounting
Ingress Protection RatingIP20
Environment
Operating Temperature0 ~ 50°C
Storage Temperature-30 ~ +75°C
Humidity10 ~ 90% RH, Non-condensing

Spesifikasjoner som oppgitt av produsenten. Med forbehold om endringer.

0 av 0 vurderinger

Gjennomsnittlig vurdering av 0 av 5 stjerner

Legg igjen en anmeldelse!

Del dine erfaringer med andre kunder.