DLW-1243 Mini Weather Station with Gas Sensing, Modbus TCP and MQTT
Outdoor mini weather station measuring wind speed and direction, temperature, humidity, CO, CO2 and NH3, with RS-485 and PoE Ethernet for Modbus RTU/TCP and MQTT integration.
- Real-time measurement of wind speed, wind direction, temperature, humidity, CO, CO2 and NH3
- Single moulded housing that mounts on a straight or horizontal rod, or to a wall
- RS-485 (Modbus RTU) and 10/100 Base-TX Ethernet with PoE (IEEE 802.3af, Class 1)
- Modbus TCP and MQTT support over Ethernet
- Integrates with the WISE controller for alarm notifications
- Built-in data logger, real-time clock and programmable watchdog timer
29 389,07 kr per stk.
| 1–9 stk. | 29 389,07 kr | |
|---|---|---|
| 10–30 stk. | 28 506,04 kr | −3 % |
| 31+ stk. | 27 913,90 kr | −5 % |
Produktinformasjon "DLW-1243 Mini Weather Station with Gas Sensing, Modbus TCP and MQTT"
The DLW-1243 CR is a compact outdoor weather station that combines meteorological sensing with hazardous gas detection in a single moulded housing. It reports wind speed, wind direction, temperature and humidity alongside CO, CO2 and NH3 readings, making it suited to engineers who need environmental data from one point on site.
Connectivity is provided by an RS-485 port for Modbus RTU and a 10/100 Base-TX Ethernet port with PoE (IEEE 802.3af, Class 1) for Modbus TCP and MQTT. The unit can also be powered from a +12 to +48 VDC terminal block. Its built-in data logger, real-time clock and watchdog timer support unattended operation, and it can be paired with the WISE controller to send alarm notifications.
The housing carries an IP54 rating and mounts on a U-bolt or to a wall. The operating range of -20 to +50 °C suits outdoor installations, and the sensors are specified for measurement ranges that include -40 to +80 ℃ for temperature. Typical deployments include greenhouse climate monitoring, remote pumping stations, port and marine air quality, and industrial exhaust monitoring.
Applications
- Smart greenhouse and agricultural monitoring
- Remote pumping station and water infrastructure monitoring
- Port and marine air quality and weather monitoring
- Industrial exhaust emissions and environmental monitoring
| Product type: | Mini weather station |
|---|---|
| Interface: | Ethernet, RS-485 |
| Protocol: | Modbus RTU, Modbus TCP, MQTT |
| Relay outputs: | Form Ax4, 100 VDC @ 1 A |
| Ports: | 1 x RS-485, 1 x RJ-45 |
| PoE: | Yes, IEEE 802.3af Class 1 |
| Power input: | +12 to +48 VDC or PoE |
| Operating temperature: | -20 ~ +50 °C |
| Mounting: | U-bolt or wall |
| Housing: | IP54 |
Spesifikasjoner
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module, Communication (Programmable) |
| LED Indicators | |
| Status | PWR: Green for normal Operation Link: Green for the Ethernet-linked Alarm: Red for an alarm condition |
| System | |
| Alarm | Weather Monitoring (Wind Speed, Wind Direction, RH/T), Particulates, Gas Monitoring (CO, CO2, NH3,) |
| Real Time Clock | Yes |
| Data Logger | Yes |
| Relay Output | PhotoMOS Relay, Form Ax4, SPST 100VDC @ 1A |
| Temperature Measurement | |
| Range | -40 ~ +80℃ |
| Resolution | 0.1℃ |
| Accuracy | ±0.5℃ |
| Humidity Measurement | |
| Range | 0 ~ 100% |
| Resolution | 0.1% |
| Accuracy | ±5% |
| Life Time | 10 years |
| CO Measurement | |
| Range | 0 ~ 1000 ppm (Electrochemical) |
| Resolution | 1 ppm |
| Accuracy | ±5% |
| Response Time | 30 seconds |
| Warm-up Time | 60 seconds |
| Life Time | 5 years |
| CO2 Measurement | |
| Range | 0 ~ 9999 ppm (NDIR) |
| Resolution | 1 ppm |
| Accuracy | ±3% |
| Response Time | 120 seconds |
| Warm-up Time | 300 seconds |
| Life Time | 15 years |
| NH3 Measurement | |
| Range | 0 ~ 100 ppm (Electrochemical) |
| Resolution | 1 ppm |
| Accuracy | ±5% |
| Response Time | <40seconds |
| Warm-up Time | 60 seconds |
| Life Time | 2 years |
| Wind Speed | |
| Rnge | 0 ~ 40 m/s |
| Accuracy | 5% |
| Resolution | 0.01 m/s |
| Wind Direction | |
| Range | 0 ~ 359° |
| Accuracy | <3° |
| Resolution | 1° |
| Ethernet | |
| Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 |
| Access Control | Password and IP Filter |
| Protocol | Modbus TCP and MQTT |
| COM Ports | |
| Ports | 1 x RS-485 |
| Baud Rate | 1200 ~ 115200 bps |
| Protocol | Modbus RTU |
| Power | |
| Consumption | PoE: 3.33 W Max Non-PoE: 3.01 W Max |
| Powered from PoE | IEEE 802.3af, Class 1 (48 V) |
| Powered from Terminal Block | +12 to +48 VDC |
| Mechanical | |
| Dimensions (mm) | 288 x 122 x 389 (W x L x H) |
| Installation | U-bolt or Wall Mounting |
| Ingress Protection Rating | IP54 |
| Weight | 2.45 KG |
| Environment | |
| Operating Temperature | -20 to +50°C |
| Storage Temperature | -30 to +75°C |
| Humidity | 10% to 90% RH, Non-condensing |
Spesifikasjoner som oppgitt av produsenten. Med forbehold om endringer.