MDC-211-ZT ZigBee Modbus Data Concentrator with Ethernet, RS-232 and RS-485

Produktinformasjon "MDC-211-ZT ZigBee Modbus Data Concentrator with Ethernet, RS-232 and RS-485"

The MDC-211-ZT CR is a Modbus data concentrator that brings serial Modbus RTU devices onto an Ethernet network. It polls connected RS-232 and RS-485 devices according to a user-defined command table, then arranges their data into a continuous address range. A remote monitoring host can therefore read data from several Modbus RTU devices in a single Modbus TCP connection, which reduces Ethernet traffic and simplifies data acquisition.

Wireless reach comes from the ZigBee mesh interface. The concentrator can connect remote, distributed ZT-2000 I/O modules and general Modbus RTU devices in locations where cabling is difficult to install, with a typical line-of-sight transmission distance of 700 m.

Setup is handled through a web-based user interface, where you can check communication status and the update frequency of each Modbus RTU command. Configuration, including the Modbus TCP ID and port, serial parameters and polling commands, can be backed up and copied as a CSV file, which suits SCADA-based monitoring systems.

Applications

  • Remote monitoring and control systems built around SCADA
  • Adding Ethernet connectivity to existing Modbus RTU devices
  • Collecting data from distributed Modbus devices where cabling is difficult to deploy
  • Integrating ZigBee wireless I/O modules into an Ethernet-based Modbus system
Product type: Data concentrator
Interface: Ethernet, RS-232, RS-485, ZigBee
Protocol: Modbus RTU, Modbus TCP
Ports: 1x Ethernet, 1x RS-232, 1x RS-485
Operating temperature: -25 ~ +75 °C
Mounting: DIN-rail
Housing: Metal

Spesifikasjoner

RF
Channels16
Transmission Power11 dBm
ZigBee
Antenna2.4 GHz, 5 dBi Omni-Directional
Transmission Distance (LoS)700 m (Typical)
Ethernet
Portsx1, 10/100 Base-TX
ProtocolModbus TCP Slave
COM Ports
Ports1x RS-232
1x RS-485
Baud Rate1200~115200 (bps)
Data FormatN81, N82, O71, O81, E71, E81, S71, S81, M71, M81
ProtocolModbus RTU Master/ Slave
Polling DefinitionUp to 240 Modbus command definitions for all ZigBee/ RS-232/ RS-485 ports
Shared Memory9600 registers for each of AI, AO, DI and DO data
Power
Consumption5W @ 24VDC
Mechanical
CasingMetal
Dimensions (mm)33 x 120 x 116 ( W x L x H)
InstallationDIN-Rail
Environment
Operating Temperature-25 ~ +75°C
Storage Temperature-30 ~ +80°C
Humidity10 ~ 90 % RH, Non-condensing

Spesifikasjoner som oppgitt av produsenten. Med forbehold om endringer.