Feltbuss-I/O
The CAN-2012C is a CANopen slave analog input module that brings 16-bit measurements onto a CAN bus network. It provides 8 differential or 16 single-ended inputs, selectable in software, and covers voltage ranges of ±10V, ±5V, ±2.5V and 0~10V as well as current ranges of ±20mA, 0~20mA and 4~20mA. Each channel can be configured individually.Built for CANopen networks, the module follows CiA 301 v4.02 and CiA 401 v2.1 and operates as an NMT slave with Node Guarding and Heartbeat error control. A default EDS file is provided for use with standard CANopen master software, and the module has passed the CiA CANopen conformance test tool, which simplifies commissioning with masters from ICP DAS or other manufacturers.Electrical features include 4 kV contact ESD protection on each channel, support for a 10 to 30 VDC supply, and isolation rated at 2500 Vrms for photo-coupling and 3000 VDC for DC-to-DC. The module mounts on DIN-rail and operates from -25 to +75 °C.ApplicationsIndustrial machinery controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoringVehicle control systemsMedical equipment control
The CAN-2015C CR connects eight RTD sensors to a CANopen network as a slave device. Each channel accepts 2-wire or 3-wire RTD sensors, with 16-bit resolution and an accuracy of +/-0.05% FSR. Engineers can read RTD values or configure the module over standard CANopen messaging.The module follows CiA 301 v4.02 and CiA 401 v2.1 and has passed validation with the CiA CANopen Conformance Test tool. A default EDS file is provided, so it can be added to a standard CANopen master with minimal configuration effort. It also works with the CANopen masters offered by ICP DAS.Diagnostic and protection features include open wire detection, individual channel configuration, a built-in 120Ω terminal resistor and 4 kV contact ESD protection on each channel. The unit runs from +10 ~ +30 VDC and is intended for DIN-rail mounting, with an operating range of -25 ~ +75 °C.ApplicationsIndustrial machine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoringVehicle control systemsMedical equipment control
The CAN-2017C CR is a CANopen slave module that brings eight differential analog inputs onto a CANopen network. It suits engineers who need to read sensor signals over CAN bus using the standard CANopen protocol, with input status and channel settings accessed through conventional CANopen objects rather than custom code.Each channel offers 16-bit resolution and a choice of input ranges from ±10 V down to ±150 mV, plus -20 mA to +20 mA when an optional external 125 Ω resistor is fitted. Channels can be configured individually, and the module supports Dynamic PDO alongside event-triggered, remotely requested, cyclic and acyclic SYNC transmission modes.The module has passed validation with the CiA CANopen Conformance Test tool and includes a default EDS file. It operates from +10 to +30 VDC, provides 3000 VDC isolation and is designed for DIN-rail installation across an operating range of -25 to +75 °C. The CR ordering code is the RoHS version of the module.ApplicationsIndustrial machine controlFactory automationVehicle control systemsMedical equipment controlRemote data acquisitionEnvironmental monitoringPackaging machine control
The CAN-2017D brings eight differential analog inputs onto a DeviceNet network as a general I/O slave. Input status can be read and the channel configuration set over the network, using the EDS file supplied for the DeviceNet master, so the module can be commissioned without custom firmware.It acts as a Group 2 Only Server (non UCMM-capable) and uses the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. Heartbeat and shutdown messages are supported. The manufacturer lists communication with Allen-Bradley 193-DNENCAT and 193-DNENCATR gateways and several OMRON DeviceNet masters.Operating temperature -25 ~ +75 ℃, DIN-rail mounted, supplied from +10 VDC to +30 VDCApplicationsIndustrial machine controlFactory automationRemote data acquisitionEnvironmental monitoringPackaging machine controlMedical equipment controlAircraft engine monitoring
CANopen Slave Module of 8-channel Thermocouple Input. Includes a CN-1824 daughter board.
DeviceNet Slave Module of 8-channel Thermocouple Input. Includes a CN-1824 daughter board.
CANopen Slave Module of 10-channel Universal AI. Includes a DB-1820 daughter board.
CANopen Slave Module of 10-channel Universal AI. Includes a DN-1822 daughter board, a 1.8m Cable.
The CAN-2022C CR is a CANopen slave I/O module that brings mixed analog and digital signals onto a CAN bus network. It combines two differential 16-bit analog inputs, two 12-bit analog outputs, four isolated wet-contact digital inputs and four isolated open-collector digital outputs in one DIN-rail unit, so a single node can cover a range of sensing and actuation tasks.Engineers typically choose this module when they need standard CANopen integration. It implements the NMT slave role and follows CiA 301 v4.02 and CiA 401 v2.1, and it has passed validation with the CiA CANopen conformance test tool. A default EDS file is supplied, so the module can be added to a standard CANopen master by importing that file, and the process data objects offer event-triggered, remotely requested, cyclic and acyclic SYNC transmission modes.The CR ordering code is listed with RoHS compliance. The module draws 1.8 W from a 10 ~ 30 VDC supply and is rated for an operating temperature of -25 ~ +75 °C. Its built-in 120 Ω terminal resistor, selectable baud rates from 10 k to 1 M and node IDs from 1 to 99 simplify bus commissioning.ApplicationsIndustrial machine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoringMedical equipment controlAircraft engine monitoring
The CAN-2024C CR is a DIN-rail CANopen slave module that drives four analogue outputs at 14-bit resolution. It suits engineers who need to control field actuators such as valves, drives and transducer inputs from a CANopen network without building custom fieldbus firmware.Each channel can be configured for 0~5 V, ±5 V, 0~10 V, ±10 V, 0~20 mA or 4~20 mA output. Voltage output accuracy is ±0.1 % of FSR and current output accuracy is ±0.2 % of FSR. The module provides a hardware watchdog, a power-on value setting, and 3000 VDC isolation for DC-to-DC, with 2500 Vrms photo-coupler isolation on the CANopen side.The module supports NMT slave operation, 10 RxPDOs and 10 TxPDOs with PDO mapping, and node IDs from 1 to 99. A default EDS file is provided, so it can be commissioned with other standard CANopen masters. The unit runs from +10 to +30 VDC, draws 2.5 W, and operates between -25 and +75 °C.ApplicationsIndustrial machine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
The CAN-2024D is a DeviceNet general I/O slave that brings four 14-bit analog outputs onto a DeviceNet network. It is a Group 2 Only Server (non UCMM-capable) and supports the Predefined Master/Slave Connection Set, so it suits networks where a DeviceNet master polls the module for its output values.Each channel can be set to one of six voltage or current ranges, with a 0.1 % of FSR accuracy specification for voltage output and 0.2 % of FSR for current output. Output status and configuration are accessed through the DeviceNet EDS file, and the module supports heartbeat and shutdown messages for network supervision.The manufacturer lists communication with the following masters and gateways: Allen-Bradley 193-DNENCAT and 193-DNENCATR, and OMRON CJ1W-DRM21, CS1W-DRM21-V1, C200HW-DRM21-V1 and 3G8F7-DRM21-E. Order code CAN-2024D CR is the RoHS-compliant variant, mounts on DIN-rail and operates from a +10 to +30 VDC supply.ApplicationsFactory automationMachine controlPackaging machine controlRemote analog output control on DeviceNet networks
The CAN-2026C CR is a CANopen slave module that brings analogue and digital I/O onto a CAN bus network. Its 6 differential analogue input channels accept a range of voltage and current signals, with individual channel configuration, while 2 analogue output channels drive voltage or current signals from the same unit.Built for standard CANopen masters, the module supports CiA 301 v4.02 and CiA 401 v2.1, with NMT slave operation and PDO mapping. A default EDS file is provided, so it can be added to a master's configuration without custom development. Isolation of 3000 VDC (DC-to-DC) and 2500 Vrms (photocoupler) is provided, and each channel has 4 kV ESD contact protection.Engineers would choose this module for distributed machine control, factory automation, remote data acquisition, environmental monitoring and packaging machine control, where a compact DIN-rail I/O node with a 10 ~ 30 VDC supply and a -25 ~ +75 °C operating range is required.ApplicationsIndustrial machine controlFactory automationRemote data acquisitionEnvironmental monitoringPackaging machine controlMedical equipment control
The CAN-2053C CR is a CANopen slave module that brings 16 isolated wet digital inputs onto a CANopen network. Each channel accepts sink or source wiring, so the same module can read PNP, NPN, TTL and relay contact signals without changing hardware. It is a practical choice where an engineer needs to read switch and alarm states over CANopen with galvanic separation between the field and the bus.The module implements CiA 301 v4.02 and CiA 401 v2.1 and has passed validation with the CiA CANopen Conformance Test tool. A default EDS file is provided, so it can be configured from a standard CANopen master. Dynamic PDO support, a configurable and savable input polarity setting, and a built-in 120Ω terminal resistor simplify commissioning and network layout. Node IDs from 1 to 99 and baud rates from 10 k to 1 M are supported.Input behaviour is defined by an ON voltage of +3.5 ~ +30 VDC and an OFF level of +1 VDC maximum, with 4 kV ESD contact protection on every channel. The I/O pair-connection function allows inputs to be linked between modules. The unit mounts on DIN-rail and operates from -25 ~ +75 °C.ApplicationsAlarm detectorSwitch detectionI/O pair-connection
The CAN-2053D CR is a DeviceNet slave I/O module that brings 16 isolated wet-type digital inputs onto a DeviceNet network. Each input accepts sink or source signals, so it can monitor PNP, NPN, TTL and relay contact outputs from field devices without changing the module.The module operates as a Group 2 Only Server, which is not UCMM-capable, and supports the predefined master/slave connection set. It provides one connection each for Explicit Messaging, Polled I/O and Bit-Strobe I/O. An EDS file is supplied for configuring the module from a DeviceNet master interface.Choose this model when you need a compact, DIN-rail mounted input node for switch detection or alarm monitoring on a DeviceNet bus. Each channel has 4 kV contact ESD protection, and the module runs from +10 VDC to +30 VDC over a -25 ~ +75 ℃ operating range.ApplicationsAlarm detectorSwitch detection
CAN-2054C CR is a CANopen slave I/O module that brings eight isolated digital inputs and eight isolated sink-type digital outputs onto a CAN bus network. It operates as an NMT slave and follows CiA DS-301 v4.02 and DSP-401 v2.1, so it can be read and configured through a standard CANopen master.The inputs are wet-type and accept sink or source signals, with an ON level from +3.5 to +30 VDC. Each output is an open-collector channel rated at 700 mA per channel, suited to switching loads from +5 to +30 VDC. Each channel has 4 kV contact ESD protection, and the module includes a default EDS file and a built-in 120 Ω terminal resistor.Pair-Connect and PDO mapping support simplify network setup, and a hardware watchdog helps the module recover from faults. The unit is DIN-rail mounted and specified for an operating range of -25 to +75 °C.ApplicationsMachine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
The CAN-2054D is a DeviceNet slave module that gives a DeviceNet master access to eight digital inputs and eight digital outputs over a single node. Input and output status can be read, and the module's configuration can be set, through the supplied EDS file, so it can be added to a DeviceNet network without custom programming.Each input channel is isolated and accepts sink or source signals from a wet contact, with an ON level of +3.5 ~ +30 VDC. Each output channel is an isolated sink-type open-collector driver rated at 700 mA per channel, with a load voltage of +5 ~ +30 VDC and 3750 Vrms intra-module isolation. The module is suited to interfacing with PNP, NPN, TTL and relay contact signals.The module operates as a Group 2 only server (non UCMM-capable) and supports the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. Heartbeat and shutdown messages are supported. It mounts on DIN-rail and is specified for an operating temperature of -25 ~ +75 ℃.ApplicationsMachine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
CAN-2055C is a CANopen slave I/O module for engineers who need to bring digital inputs and outputs onto a CAN bus network. It follows CiA 301 v4.02 and CiA 401 v2.1, so digital I/O status can be read and configured through standard CANopen objects, and it works with any standard CANopen master once the default EDS file is loaded.The module provides 8 isolated sink/source digital inputs with a wet-contact type, and 8 isolated source (PNP) digital outputs rated at 700mA per channel with a load voltage of +10 ~ +30 VDC. Each channel carries 4KV ESD protection contact, which helps the module tolerate harsh field wiring.Communication is configured through 10 RxPDOs and 10 TXPDOs with PDO mapping, using event-triggered, remotely-requested, cyclic and acyclic SYNC modes. Error control is provided by Node Guarding or Heartbeat Producer, and the module includes a built-in 120Ω terminal resistor. The unit is RoHS compliant and mounts on a DIN-rail.ApplicationsIndustrial machine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
CAN-2057C CR is a CANopen slave module that drives 16 isolated open-collector sink (NPN) digital outputs. It follows DS-301 v4.02 and DSP-401 v2.1, so the outputs can be set and monitored over standard CANopen messaging from any conformant master. Each channel handles up to 100 mA at a load voltage of +5 ~ +30 VDC, which suits relays, indicators and resistive loads.The module has passed the CiA CANopen Conformance Test tool and ships with a default EDS file, so it can be added to a standard CANopen master without custom driver work. Output polarity and error-value behaviour can be configured and saved, and dynamic PDO support gives flexibility in how process data is mapped.Supplied with CE, UKCA, FCC, RoHS and WEEE certifications, the module is intended for DIN-rail installation across the -25 ~ +75 °C operating range. Its built-in 120Ω terminal resistor and hardware watchdog help simplify network termination and fault handling.ApplicationsAlarm detectorSwitch detectionI/O pair-connectionRelay drivingResistance load drivingLight control
The CAN-2057D CR is a DeviceNet slave module that gives a DeviceNet network 16 isolated digital outputs. Each channel is an NPN (sink) open-collector output rated for loads from +5 to +30 VDC at up to 100 mA per channel, making it a straightforward choice for alarm outputs and switch control in machine and factory automation.The module operates as a Group 2 only server and is not UCMM-capable. It supports the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. DeviceNet heartbeat and shutdown messages are supported, and an EDS file is provided for configuring the output status through a DeviceNet master interface. The manufacturer lists prior communication with Allen-Bradley 193-DNENCAT and 193-DNENCATR and several OMRON DeviceNet masters and gateways.Power is supplied from +10 to +30 VDC, with a consumption of 1.5 W. The module is designed for DIN-rail mounting and an operating temperature range of -25 to +75 °C, and carries CE, FCC, RoHS and WEEE marks.ApplicationsAlarm outputSwitch controlDriving relaysResistive loadsMachine controlFactory automation
The CAN-2060C CR is a DIN-rail CANopen slave module that combines four isolated digital inputs, usable as sink or source wet or dry contacts, with four Form A (SPST-NO) relay outputs. It lets a CANopen master read input status and switch relays over a single CAN bus connection.Engineers will find it useful where a CANopen network needs both sensing and switching at the machine level. Digital I/O status can be accessed and the configuration set using standard CANopen protocol, and the module supports PDO mapping with a range of PDO transmission modes. Its built-in 120Ω terminal resistor and node IDs from 1 to 99 simplify network setup.The module is supplied with a default EDS file for straightforward integration with standard CANopen masters. It carries CE, UKCA, FCC, RoHS and WEEE marks and operates from a 10 to 30 VDC supply across -25 to +75 °C.ApplicationsIndustrial machine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
The CAN-2084C is a CANopen slave module that brings 4 or 8 counter and frequency input channels onto a CAN bus network. It suits engineers who need to count events, measure frequency or monitor position from quadrature encoders within a CANopen system.The module offers five counter modes: Up Counter, Frequency, Up/Down Counter, Dir/Pulse Counter and A/B Phase Counter. A digital filter reduces the effect of noise on the inputs, and each channel has 4 kV contact ESD protection. It operates as an NMT slave and supports PDO mapping with 10 RxPDOs and 10 TxPDOs.The module has passed validation with the CiA CANopen conformance test tool and provides a default EDS file, so it can be integrated with a standard CANopen master. It is designed for DIN-rail mounting and has an operating temperature range of -25 ~ +75 °C.ApplicationsEvent counting and totalisingFrequency measurementPosition monitoring with quadrature encodersRemote data acquisitionFactory automationPackaging machine control
CAN-2088C CR is a CANopen slave module that turns digital outputs into PWM signals with adjustable frequency and duty cycle. Its eight PWM channels can drive analogue control circuits from a fieldbus master, so engineers can achieve proportional-style control without dedicated analogue output hardware.Each of the eight digital input channels carries a 32-bit counter running at up to 500 kHz, allowing high speed pulse counting alongside the PWM outputs in the same node. PWM can be triggered by software or hardware, and each output can be started individually or all outputs can be triggered synchronously. Burst and Continuous output modes are supported.The module follows CiA 301 v4.02 and CiA 401 v2.1, has passed the CANopen conformance test and is supplied with an EDS file for configuring the CANopen master. It mounts on DIN-rail and operates from -25 ~ +75 °C.ApplicationsAnalogue-style control circuits driven by PWM outputsCANopen networks requiring combined PWM output and high speed counting
CAN-2088D is a DeviceNet slave module that generates PWM signals on eight outputs and counts pulses on eight high speed inputs. It suits engineers who need precise hardware-timed output waveforms and fast counting without a dedicated motion controller, with the DeviceNet master handling supervision.Each PWM channel can be triggered individually or all together in synchronous mode, using either software or hardware triggering. Burst and continuous output modes are supported, with burst counts from 1 to 65535. Each digital input channel includes a 32-bit counter running at up to 500 kHz. The module is supplied with an EDS file for configuring the DeviceNet master interface.The manufacturer lists communication with several DeviceNet masters and gateways, including Allen-Bradley 193-DNENCAT and 193-DNENCATR, and OMRON CJ1W-DRM21, CS1W-DRM21-V1, C200HW-DRM21-V1 and 3G8F7-DRM21-E. The module mounts on a DIN rail and operates from +10 VDC to +30 VDC over -25 to +75 °C.ApplicationsMotor position and speed controlLamp brightness dimmingFan speed controlHigh speed counting
CAN-8123-G is a CANopen slave unit for distributed I/O on CAN bus networks. It follows CiA 301 v4.02 and CiA 401 v2.1, so it can be integrated with standards-based CANopen masters. Process data is handled through PDOs with several transmission modes, and PDO mapping is available for configuring which data is exchanged.A single expansion slot lets you tailor the I/O to the application. The unit accepts a range of ICP DAS digital and analogue slot modules from the I-87K and I-8000 series, covering digital inputs, digital outputs, analogue inputs and analogue outputs. A utility is supplied to generate the EDS file dynamically, which is based on CiA SP306 and is intended for compatibility with different CANopen master interfaces.The unit has an integrated 120Ω terminating resistor, isolation ratings of 3000 VDC (DC-to-DC) and 2500 Vrms (photo-coupler), and an operating range of -25 ~ +75 °C. It mounts on a DIN rail and is suited to industrial machinery, laboratory equipment, maritime and medical installations among other sectors.ApplicationsIndustrial MachineryLaboratory Equipment & ResearchRestaurant AppliancesMaritimeMedicalSpecialty Vehicles