DeviceNet
The CAN-2017D brings eight differential analog inputs onto a DeviceNet network as a general I/O slave. Input status can be read and the channel configuration set over the network, using the EDS file supplied for the DeviceNet master, so the module can be commissioned without custom firmware.It acts as a Group 2 Only Server (non UCMM-capable) and uses the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. Heartbeat and shutdown messages are supported. The manufacturer lists communication with Allen-Bradley 193-DNENCAT and 193-DNENCATR gateways and several OMRON DeviceNet masters.Operating temperature -25 ~ +75 ℃, DIN-rail mounted, supplied from +10 VDC to +30 VDCApplicationsIndustrial machine controlFactory automationRemote data acquisitionEnvironmental monitoringPackaging machine controlMedical equipment controlAircraft engine monitoring
The CAN-2024D is a DeviceNet general I/O slave that brings four 14-bit analog outputs onto a DeviceNet network. It is a Group 2 Only Server (non UCMM-capable) and supports the Predefined Master/Slave Connection Set, so it suits networks where a DeviceNet master polls the module for its output values.Each channel can be set to one of six voltage or current ranges, with a 0.1 % of FSR accuracy specification for voltage output and 0.2 % of FSR for current output. Output status and configuration are accessed through the DeviceNet EDS file, and the module supports heartbeat and shutdown messages for network supervision.The manufacturer lists communication with the following masters and gateways: Allen-Bradley 193-DNENCAT and 193-DNENCATR, and OMRON CJ1W-DRM21, CS1W-DRM21-V1, C200HW-DRM21-V1 and 3G8F7-DRM21-E. Order code CAN-2024D CR is the RoHS-compliant variant, mounts on DIN-rail and operates from a +10 to +30 VDC supply.ApplicationsFactory automationMachine controlPackaging machine controlRemote analog output control on DeviceNet networks
The CAN-2053D CR is a DeviceNet slave I/O module that brings 16 isolated wet-type digital inputs onto a DeviceNet network. Each input accepts sink or source signals, so it can monitor PNP, NPN, TTL and relay contact outputs from field devices without changing the module.The module operates as a Group 2 Only Server, which is not UCMM-capable, and supports the predefined master/slave connection set. It provides one connection each for Explicit Messaging, Polled I/O and Bit-Strobe I/O. An EDS file is supplied for configuring the module from a DeviceNet master interface.Choose this model when you need a compact, DIN-rail mounted input node for switch detection or alarm monitoring on a DeviceNet bus. Each channel has 4 kV contact ESD protection, and the module runs from +10 VDC to +30 VDC over a -25 ~ +75 ℃ operating range.ApplicationsAlarm detectorSwitch detection
The CAN-2054D is a DeviceNet slave module that gives a DeviceNet master access to eight digital inputs and eight digital outputs over a single node. Input and output status can be read, and the module's configuration can be set, through the supplied EDS file, so it can be added to a DeviceNet network without custom programming.Each input channel is isolated and accepts sink or source signals from a wet contact, with an ON level of +3.5 ~ +30 VDC. Each output channel is an isolated sink-type open-collector driver rated at 700 mA per channel, with a load voltage of +5 ~ +30 VDC and 3750 Vrms intra-module isolation. The module is suited to interfacing with PNP, NPN, TTL and relay contact signals.The module operates as a Group 2 only server (non UCMM-capable) and supports the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. Heartbeat and shutdown messages are supported. It mounts on DIN-rail and is specified for an operating temperature of -25 ~ +75 ℃.ApplicationsMachine controlFactory automationPackaging machine controlRemote data acquisitionEnvironmental monitoring
The CAN-2057D CR is a DeviceNet slave module that gives a DeviceNet network 16 isolated digital outputs. Each channel is an NPN (sink) open-collector output rated for loads from +5 to +30 VDC at up to 100 mA per channel, making it a straightforward choice for alarm outputs and switch control in machine and factory automation.The module operates as a Group 2 only server and is not UCMM-capable. It supports the predefined master/slave connection set, with one connection each for explicit messaging, polled I/O and bit-strobe I/O. DeviceNet heartbeat and shutdown messages are supported, and an EDS file is provided for configuring the output status through a DeviceNet master interface. The manufacturer lists prior communication with Allen-Bradley 193-DNENCAT and 193-DNENCATR and several OMRON DeviceNet masters and gateways.Power is supplied from +10 to +30 VDC, with a consumption of 1.5 W. The module is designed for DIN-rail mounting and an operating temperature range of -25 to +75 °C, and carries CE, FCC, RoHS and WEEE marks.ApplicationsAlarm outputSwitch controlDriving relaysResistive loadsMachine controlFactory automation
CAN-2088D is a DeviceNet slave module that generates PWM signals on eight outputs and counts pulses on eight high speed inputs. It suits engineers who need precise hardware-timed output waveforms and fast counting without a dedicated motion controller, with the DeviceNet master handling supervision.Each PWM channel can be triggered individually or all together in synchronous mode, using either software or hardware triggering. Burst and continuous output modes are supported, with burst counts from 1 to 65535. Each digital input channel includes a 32-bit counter running at up to 500 kHz. The module is supplied with an EDS file for configuring the DeviceNet master interface.The manufacturer lists communication with several DeviceNet masters and gateways, including Allen-Bradley 193-DNENCAT and 193-DNENCATR, and OMRON CJ1W-DRM21, CS1W-DRM21-V1, C200HW-DRM21-V1 and 3G8F7-DRM21-E. The module mounts on a DIN rail and operates from +10 VDC to +30 VDC over -25 to +75 °C.ApplicationsMotor position and speed controlLamp brightness dimmingFan speed controlHigh speed counting
CAN-8124-G is a DeviceNet slave remote I/O unit that links local field I/O to a DeviceNet master. Its single expansion slot lets you add digital or analogue channels to suit each machine, so the I/O mix can be matched to the application.The slot accepts DI, DO, AI and AO modules from the I-87K or I-8000 series. A CAN Slave Utility is available to generate an EDS file dynamically, based on DeviceNet, which is intended to work with different DeviceNet master interfaces.Node address and baud rate are set with rotary switches, supporting 125 k, 250 k and 500 k. The unit supports up to 64 nodes, has a jumper-selectable 120 Ω terminal resistor, runs from +10 VDC to +30 VDC and operates between -25 and +75 ℃.ApplicationsAutomotiveFood & BeveragePackagingHigh-speed AssemblyPulp & PaperSemiconductor FabricationControl System
CAN-8224-G is a DeviceNet slave remote I/O unit that accepts two plug-in I/O modules, letting you build the channel count and signal mix your application needs. It follows the DeviceNet Specification Volume I and II, Release 2.0, and can address up to 64 nodes.Expansion slots accept I-87K or I-8000 series digital input, digital output, analogue input and analogue output modules. The unit is configured with rotary switches for MAC ID and baud rate, and an EDS file can be generated with the CAN Slave Utility for use with different DeviceNet masters.Supports the Poll, Bit-Strobe and Change of State/Cyclic I/O operating modesGalvanic isolation of 3000 VDC (DC-to-DC) and 2500 Vrms (photo-coupler)ApplicationsAutomotiveFood & BeveragePackagingHigh-speed AssemblyPulp & PaperSemiconductor FabricationControl System
The CAN-8424-G is a DeviceNet remote I/O unit built around a modular backplane with four slots, so engineers can assemble the I/O mix their application needs. It suits data acquisition and control tasks where a DeviceNet network needs local I/O under a single controller.Configuration is handled with the CAN-8424 Utility, which connects through the RS-232 utility port. The tool generates the EDS file for the I/O modules fitted, so the unit can be integrated into a DeviceNet scan list without manual device description work.Supports Poll, Bit-Strobe and Change of State/Cyclic I/O operating modesRated for the DC power range of +10 VDC to +30 VDC, with a typical consumption of 2.5 WDesigned for DIN-rail mounting within an operating range of -25 ~ +75 ℃ApplicationsDiagnostic systems for wheeled tractors